Deck Material Calculator
Enter the deck size, decking board, joist layout, beam, and post height to get one combined material list: deck boards by stock length, joists and framing lumber, the beam and posts, footing concrete, and every fastener and hanger.
Quick answer: A deck material list adds up decking, framing, beam, posts, footings and fasteners from the deck size. Example: a 16 × 12 ft deck needs 29 16-foot deck boards, 13 joists, 4 posts and 10 80-lb bags of concrete for the footing pads (piers extra), about 742 linear feet of lumber with 10% extra.
Free · no sign-up · By Clinton Munkres, Founder, Boringhaus ·
Deck
Framing
Material list · lumber incl. +10% waste
Decking
- Deck area
- 192 sq ft
- Board rows
- 26
- Decking lumber
- 458 lin ft
- Boards to buy
- 29 × 16 ft
Framing
- Joists
- 13
- Framing lumber
- 223 lin ft
- Blocking pieces
- 12
- Joist span check
- OK
Posts, beam & footings
- Posts
- 4
- Post spacing
- 5'-4"
- Beam lumber
- 35 lin ft
- Post lumber
- 13 lin ft
- Footing size
- 21" rd / 18" sq × 8"
- Concrete
- 5.8 cu ft
- Post height check
- OK
- Beam span check
- OK
Fasteners & hardware
- Deck screws
- 676
- Joist hangers
- 13
- Hanger nails
- 130
- Ledger lags
- 24
- Beam bolts
- 8
- Post bases + caps
- 4
- Total lumber
- 729 lin ft
A 16 × 12 ft deck (192 sq ft) takes 26 rows of decking — 29 boards at 16 ft — on 13 2×10 joists, a (2) 2×10 beam on 4 6×6 posts, and 4 footings.
Counts cover decking, joists, rim and ledger, blocking, one beam on 6×6 posts, footings, and the main fasteners. Railings, stairs, and a second beam are not included — see the deck stairs calculator for stairs.
The formula & reference figures
Decking rows = Width ÷ (board width + gap); linear feet = Rows × length. Joists = Length ÷ spacing + 1, each the width long. Posts = Beam length ÷ AWC maximum beam span, rounded up, + 1. Footings per AWC DCA 6 Table 4. Screws = 2 per board per joist; hangers = 1 per joist; 2 ledger lags per 16 in; 2 bolts per post.
| Decking rows | Deck width ÷ (board width + gap), rounded up |
| Joists | Deck length ÷ spacing, rounded up, + 1; one hanger (10 nails) each |
| Rim + ledger | 2 × deck length; ledger at least 2×8 (DCA 6 Table 2 footnote 6) |
| Blocking | One row at mid-span, (joists − 1) pieces |
| Beam + posts | Span per Table 3A; posts = bays + 1; 6×6 posts; footings per Table 4 |
| Fasteners | 2 deck screws per board per joist · 2 ledger lags per 16" · 2 beam bolts per post |
| Waste | Adjustable, default 10% on all lumber; diagonal decking +15% |
Beam spans and footings
| Species | Beam | ≤ 6' joists | ≤ 8' joists | ≤ 10' joists | ≤ 12' joists | ≤ 14' joists | ≤ 16' joists | ≤ 18' joists |
|---|---|---|---|---|---|---|---|---|
| Southern Pine | (2) 2×6 | 6'-8" | 5'-8" | 5'-1" | 4'-7" | 4'-3" | 4'-0" | 3'-9" |
| (2) 2×8 | 8'-6" | 7'-4" | 6'-6" | 5'-11" | 5'-6" | 5'-1" | 4'-9" | |
| (2) 2×10 | 10'-1" | 8'-9" | 7'-9" | 7'-1" | 6'-6" | 6'-1" | 5'-9" | |
| (2) 2×12 | 11'-11" | 10'-4" | 9'-2" | 8'-4" | 7'-9" | 7'-3" | 6'-9" | |
| (3) 2×6 | 7'-11" | 7'-2" | 6'-5" | 5'-10" | 5'-5" | 5'-0" | 4'-9" | |
| (3) 2×8 | 10'-7" | 9'-3" | 8'-3" | 7'-6" | 6'-11" | 6'-5" | 6'-1" | |
| (3) 2×10 | 12'-9" | 11'-0" | 9'-9" | 8'-9" | 8'-3" | 7'-8" | 7'-3" | |
| (3) 2×12 | 15'-0" | 13'-0" | 11'-7" | 10'-6" | 9'-9" | 9'-1" | 8'-7" | |
| Douglas Fir-Larch, Hem-Fir, SPF, Redwood, Western Cedars, Ponderosa & Red Pine | 3×6 or (2) 2×6 | 5'-2" | 4'-5" | 3'-11" | 3'-7" | 3'-3" | 2'-10" | 2'-6" |
| 3×8 or (2) 2×8 | 6'-7" | 5'-8" | 5'-1" | 4'-7" | 4'-3" | 3'-10" | 3'-5" | |
| 3×10 or (2) 2×10 | 8'-1" | 7'-0" | 6'-3" | 5'-8" | 5'-3" | 4'-10" | 4'-5" | |
| 3×12 or (2) 2×12 | 9'-5" | 8'-2" | 7'-3" | 6'-7" | 6'-1" | 5'-8" | 5'-4" | |
| (3) 2×6 | 7'-1" | 6'-5" | 5'-9" | 5'-3" | 4'-10" | 4'-6" | 4'-3" | |
| (3) 2×8 | 9'-5" | 8'-3" | 7'-4" | 6'-8" | 6'-2" | 5'-9" | 5'-5" | |
| (3) 2×10 | 11'-9" | 10'-2" | 9'-1" | 8'-3" | 7'-7" | 7'-1" | 6'-8" | |
| (3) 2×12 | 13'-8" | 11'-10" | 10'-6" | 9'-7" | 8'-10" | 8'-3" | 7'-10" | |
| 4×6 | 6'-2" | 5'-3" | 4'-8" | 4'-3" | 3'-11" | 3'-8" | 3'-5" | |
| 4×8 | 8'-2" | 7'-0" | 6'-3" | 5'-8" | 5'-3" | 4'-11" | 4'-7" | |
| 4×10 | 9'-8" | 8'-4" | 7'-5" | 6'-9" | 6'-3" | 5'-10" | 5'-5" | |
| 4×12 | 11'-2" | 9'-8" | 8'-7" | 7'-10" | 7'-3" | 6'-9" | 6'-4" |
| Beam span | Joist span | Southern Pine | Douglas Fir-Larch | Hem-Fir, Western Cedars | Redwood | Ponderosa Pine, Red Pine, SPF | Round | Square | Thick |
|---|---|---|---|---|---|---|---|---|---|
| ≤ 6' | ≤ 10' | 14' | 14' | 14' | 14' | 14' | 18" | 16" × 16" | 7" |
| ≤ 6' | ≤ 14' | 14' | 14' | 14' | 14' | 14' | 21" | 18" × 18" | 8" |
| ≤ 6' | ≤ 18' | 14' | 14' | 12' | 14' | 11' | 24" | 21" × 21" | 10" |
| ≤ 8' | ≤ 10' | 14' | 14' | 14' | 14' | 14' | 20" | 18" × 18" | 8" |
| ≤ 8' | ≤ 14' | 14' | 14' | 14' | 14' | 11' | 24" | 21" × 21" | 10" |
| ≤ 8' | ≤ 18' | 14' | 13' | 11' | 12' | 8' | 27" | 24" × 24" | 11" |
| ≤ 10' | ≤ 10' | 14' | 14' | 14' | 14' | 12' | 23" | 20" × 20" | 9" |
| ≤ 10' | ≤ 14' | 14' | 13' | 11' | 13' | 8' | 27" | 24" × 24" | 11" |
| ≤ 10' | ≤ 18' | 12' | 11' | 8' | 11' | 2' | 31" | 27" × 27" | 13" |
| ≤ 12' | ≤ 10' | 14' | 14' | 12' | 14' | 10' | 25" | 22" × 22" | 10" |
| ≤ 12' | ≤ 14' | 13' | 12' | 9' | 11' | 5' | 30" | 26" × 26" | 13" |
| ≤ 12' | ≤ 18' | 11' | 9' | 6' | 9' | 2' | 34" | 30" × 30" | 15" |
| ≤ 14' | ≤ 10' | 14' | 13' | 11' | 13' | 8' | 27" | 24" × 24" | 11" |
| ≤ 14' | ≤ 14' | 11' | 10' | 7' | 10' | 2' | 32" | 29" × 29" | 14" |
| ≤ 14' | ≤ 18' | 9' | 8' | 2' | 8' | NP | 37" | 33" × 33" | 16" |
| ≤ 16' | ≤ 10' | 13' | 12' | 10' | 12' | 6' | 29" | 26" × 26" | 12" |
| ≤ 16' | ≤ 14' | 10' | 9' | 5' | 9' | 2' | 35" | 31" × 31" | 15" |
| ≤ 16' | ≤ 18' | 7' | 5' | 2' | 7' | NP | 40" | 35" × 35" | 18" |
| ≤ 18' | ≤ 10' | 12' | 11' | 8' | 11' | 2' | 31" | 27" × 27" | 13" |
| ≤ 18' | ≤ 14' | 9' | 8' | 2' | 8' | NP | 37" | 33" × 33" | 16" |
| ≤ 18' | ≤ 18' | 5' | 2' | 2' | 6' | NP | 42" | 37" × 37" | 19" |
Source: American Wood Council, DCA 6-2015 — Prescriptive Residential Wood Deck Construction Guide. Joist spans from Table 2, beam spans from Table 3A, post heights and footings from Table 4 of AWC DCA 6-2015. AWC DCA 6-2015 Tables 3A (p. 6) and 4 (p. 12): 40 psf live + 10 psf dead load, No. 2 grade, wet service, 1,500 psf soil, 2,500 psi concrete. Incising assumed for Douglas Fir-Larch, Hem-Fir and SPF (footnote 4); joists and rim joists that carry guard posts must be at least 2×8 (Table 2 footnote 6). Confirm with your building department.
Key numbers
- A 12 × 16-foot deck needs 26 rows of 5.5-inch deck boards, or 416 linear feet of decking.
- A 16-foot deck at 16 inches on center needs 13 joists and 13 joist hangers.
- A 12 × 16-foot deck with 13 joists takes 676 deck screws at 2 per board per joist.
- A deck ledger needs 2 half-inch lag screws or bolts per 16 inches of length.
- Plan 2 through-bolts per post where the beam bears on 6×6 posts.
- Order about 10% extra lumber for a deck, and 15% extra decking for a diagonal pattern.
How to estimate deck material materials
A deck material list is five smaller estimates stacked up, and this calculator runs all of them from one set of dimensions. The decking count divides the width by the board width plus gap for the number of rows, multiplies by the length for linear feet, and converts that to boards at your stock length. The framing count spaces joists along the length, each spanning the width, and adds the ledger, rim joist, one row of blocking, and a hanger per joist. Every lumber line carries the same waste allowance — 10% by default, with an extra 15% on decking for a diagonal pattern.
The beam and posts come from the AWC DCA 6 tables rather than a rule of thumb. The beam runs the length of the deck at the outer end of the joists; its maximum span between posts depends on the species, how many plies deep it is, and how long the joists are, and the post count follows. The posts are 6×6 (the only size in the 2015 guide), their footings are sized from the same table, and the concrete is the footing pad only — enter the frost-depth pier separately in the deck footing calculator if you need the full pour. If a joist or beam span is over its table limit, the list flags it rather than silently counting lumber that will not pass inspection.
Hardware is where estimates usually fall short. The list counts two deck screws per board at every joist, one joist hanger per joist with ten nails each, two ½-inch lag screws or bolts per 16 inches of ledger (the DCA 6 pattern for most joist spans), a post base and cap per post, and two through-bolts per post for the beam. Use hot-dip galvanized or stainless hardware with treated lumber. Railings, stairs, and a second beam on a freestanding deck are not included — the deck stairs calculator covers the stairs, and the deck cost calculator prices this whole list.
Frequently asked questions
What materials do I need to build a deck?+
Decking boards, joists, a ledger and rim joist, blocking, a beam, posts, footings with concrete, joist hangers, screws, ledger fasteners, post bases and caps, and beam bolts — plus railings and stairs if the deck is more than 30 inches off the ground. This calculator lists everything except the railing and stairs.
How much lumber do I need for a 12×16 deck?+
With 5.5-inch boards at a 1/8-inch gap, 16-foot stock, 2×10 joists at 16 inches, a two-ply 2×10 beam on four 3-foot 6×6 posts, and 10% waste: about 29 deck boards (458 linear feet), 13 joists plus rim and ledger and blocking (about 213 linear feet of 2×10), 35 linear feet of beam, and 13 linear feet of post — roughly 720 linear feet of lumber in all.
How many deck boards do I need?+
Divide the deck width by the board width plus gap for the rows, multiply by the length for linear feet, add waste, and divide by the stock length. A 12-foot-wide deck takes 26 rows of 5.5-inch boards; at 16 feet long that is 416 linear feet, or 29 sixteen-foot boards with 10% waste.
How many joists, hangers, and screws does a deck need?+
Joists are the deck length divided by the spacing plus one — 13 for a 16-foot deck at 16 inches on center — with one hanger per joist. Screws are two per board at every joist crossing: 26 rows × 13 joists × 2 = 676 screws for a 12×16 deck. Add the ledger, rim joist, and blocking.
How many posts and footings does a deck need?+
One post per beam support and one footing per post. The beam span between posts comes from the AWC table — 7 feet 1 inch for two 2×10 Southern Pine with 12-foot joists — so a 16-foot beam needs four posts and four footings. A freestanding deck with two beams doubles it.
How much concrete for deck footings?+
The calculator sizes each footing from AWC DCA 6 Table 4 and counts the pad concrete — about 1.6 cubic feet (three 80-lb bags) for a 21-inch round footing 8 inches thick. Add the pier to frost depth in the deck footing calculator; a 36-inch pier adds about 2.4 cubic feet per post.
What size beam do I need for my deck?+
It depends on the joist span and the species. Two 2×10s are the common choice for a 12-foot-wide deck, giving a 7-foot post spacing in Southern Pine. Pick a beam above and the calculator sets the post count; if you want fewer posts, go to three plies or a 2×12.
How much extra material should I order?+
About 10% on all lumber for culls, cuts, and the occasional bad board, and 15% more on decking laid diagonally. Fasteners and hangers are counted exactly, so add a box of screws for the inevitable drops. The waste field applies to every lumber line.
Does the list include railings and stairs?+
No. Railing posts, rails, balusters, and stair stringers and treads depend on the layout and the height off the ground. Use the deck stairs calculator for the stairs; railings need about one 4×4 post per 6 feet plus top and bottom rails and a baluster every 4 inches.
What span limits does the calculator check?+
The joist span against AWC DCA 6 Table 2 for the size, species, and spacing, and the beam span against Table 3A. It also checks the 6×6 post height against Table 4. Anything over the table gets a warning instead of a count.
Is this deck material calculator free?+
Yes — it is free, needs no sign-up, and runs entirely in your browser, so nothing you enter is stored or sent anywhere.